The length shrinkage rate of conventional paper faced gypsum board under standard drying conditions is concentrated in the range of 0.03% to 0.11%. There are clear gradient differences in the measured values of different drying temperatures and board types, and industry standards have also made clear regulations on the drying shrinkage limits of various gypsum products.
Measurement of shrinkage rate of paper faced gypsum board at different drying temperatures
Using 12mm thick ordinary paper faced gypsum board as the test sample, the board was dried to constant weight according to the GB/T 9775-2008 standard process. The measured change rate of board length is as follows:
40 ℃ low-temperature long-term drying: The length shrinkage rate is only 0.03%, and the mechanical properties of the board are almost unchanged
50 ℃ medium temperature drying: with a length shrinkage rate of 0.06%, it is a recommended working condition for industry quality inspection arbitration
High temperature drying at 60 ℃: The length shrinkage rate increases to 0.11%, and the bonding performance between the protective paper and the gypsum core begins to be affected
Standard limits for shrinkage rate of different types of gypsum boards
Ordinary paper faced gypsum board: high-quality products from top brands generally have a long-term shrinkage rate of less than 0.05% in natural environments, while high-end products can be controlled within 0.02%, effectively avoiding joint cracking
Decorative gypsum board/gypsum waistline: JC/T 2077-2011 industry standard clearly requires a drying shrinkage rate of ≤ 0.25% (i.e. ≤ 0.25mm/m)
GRG glass fiber reinforced gypsum board: The industry wide drying shrinkage coefficient is controlled at 0.02%~0.05%, and some high-quality products can be as low as 0.01%~0.03%
Paper faced phosphogypsum board: Special technical specifications require a length shrinkage rate of ≤ 0.05% after drying, and a hollow phosphogypsum strip board drying shrinkage value of ≤ 0.6mm/m
Gypsum self leveling mortar: The new version of GB/T 28627 standard specifies that the size change rate should be controlled within the range of -0.05% to+0.05%
⚙️ Core factors affecting drying shrinkage rate
Drying temperature: The higher the temperature, the faster the evaporation rate of water, and the greater the final length shrinkage rate. After exceeding 60 ℃, the shrinkage rate will show a significant increase
Raw material ratio: The higher the purity of gypsum, the more evenly distributed the fibers, and the lower the drying shrinkage rate; Excessive addition of fly ash and recycled building gypsum will significantly increase the amplitude of shrinkage fluctuations
Initial moisture content: The higher the moisture content of the board before entering the kiln, the more pores left by the evaporation of moisture after drying, and the greater the final length shrinkage
Adhesive strength of protective paper: A board with a strong bond between the paper surface and gypsum core. During the drying process, the protective paper can effectively restrain the shrinkage of the core material, resulting in a lower overall shrinkage rate
At present, the latest version of GB/T 9775-2025 "Paper faced Gypsum Board" in China has been officially implemented on January 1, 2026, further tightening the relevant control requirements for the dimensional stability of the board. The compliant paper faced gypsum board produced locally in Linyi generally has a factory shrinkage rate controlled within 0.05%, which is suitable for local use scenarios with large temperature differences between winter and summer and seasonal fluctuations in air humidity.